Scientific Instruments | 622 Lunt Ave, Schaumburg, IL 60193
AVAILABLE 24/7

AC or DC Ammeter replaces old Analog Ammeter, and reads up to 19KA

$1,200.00

DC & True RMS AC Ammeter

SI-19KA-PM Digital Panel Meter designed to replace the oldAnalog Ammeters that had a 2.75” to 4” diameter mounting hole to provide a greater accuracy of output amperes with infinite hold, auto reset and update functions that will meet or exceed all industrial and military requirements.

High visibility LED digital display shows the output current in kilo amperes. The meters holds this reading indefinitely for accurate recording of each mag shot. As each mag shot is taken the meter will automatically reset, compute and display the new reading in less than .5 seconds.

Standard Meters are calibrated for either TRUE AVERAGE DC or TRUE RMS AC ,for operation from your existing 50mv/1000 Amp meter shunt (or other value shunt) either in place of or in conjunction with your machine’s meter. Meters are pre calibrated, and there is an external gain adjust in case you need a minor trim due to you existing meter shunt accuracy. This ammeter will take the true DC average of any DC waveform, whether it is 1 phase FWDC, or HWDC, or 3phase FWDC, without having to re-adjust again the gain setting.

This meter also reads the TRUE RMS AC current of any AC waveform, regardless of crest factor.

SKU: SI-19KA-PM Category:

Description

Features & Advantages

  • Meter gain calibration adjustment on front panel
  • AUTO UPDATE/MANUAL switch
  • Holds last reading or continuous reading
  • LED Display, 3 1/2 digits
  • Mounting screws for front panel
  • Front panel face plate, 1/8 DIN case available
  • AC power input terminals
  • Shunt input terminals
  • Shunt Triggered

Specifications

  • Basic Accuracy = DC .5% , AC 2% of reading + /- 2LSB counts
  • Range =100 to 19,990 amps, in 10 amp increments
  • DPM Display = 3 ½ LED .56” (14mm) digit height
  • Conversion Time = 280msec
  • Auto Reset Time = 1 second
  • Signal Input = 50mv/1000A Meter Shunt standard
  • Input Impedance = 100Ω
  • Power Line Input = 90 to120 VAC, 4VA, 50/60Hz
  • Operating Temperature = 32 to 120°F (0 to 49°C)
  • Dimensions HxWxD = 4 x 4.3 x 2.5 inches
  • Weight = 8oz. (227g)

DOWNLOAD MODEL SI-19KA PANEL MOUNT SPEC SHEET